
Iridium Coated Titanium Anode for Pcb Reverse Pulse Copper Plating
Xubo specializes in manufacturing PCB special titanium anodes! Lower consumption, longer service life
Product Introduction
Due to the design requirements of circuit boards tend to fine wire diameter, high density, fine aperture (high depth to diameter ratio, even micro-through hole), filling blind holes, the traditional DC plating becomes more and more unable to meet the requirements, especially in the through-hole plating of the aperture center of the plating layer, usually appear at both ends of the aperture of the copper layer is too thick but the center of the copper layer is not enough phenomenon. This uneven plating will affect the effect of current delivery and directly lead to poor product quality. In order to balance the thickness of copper on the surface, especially in the holes and microvias, the current density is forced to be reduced, but this will extend the plating time to an unacceptable level. With the development of plating processes, Iridium Coated Titanium Anode For PCB Reverse Pulse Copper Plating and chemical additives suitable for the plating process, shortening the plating time became a reality and these problems can be overcome by the reverse pulse plating process.
Typical process conditions:
| Electrolyte | CuSO4-5H2O, 100-300 g/l |
| H2SO4, 50-150 g/l | |
| Temperature | 20- 70 °C |
| Current density | Usually 500-1000A/M2 forward pulse current and three times reverse pulse current; generally 19ms forward pulse, 1ms reverse; or adjust the current density and pulse time according to the process |
| Anode type | Special iridium metal oxide mixture coating,special requirements for the consumption of additives |
Titanium Anode Test Conditions:
|
Electrolyte |
2L |
|
Sulfuric acid |
200ml/L |
|
Temperature |
80°C |
|
Current |
20A |
|
Anode size |
2c㎡ |
|
Anode and cathode distance |
12.5CM |
|
Current density |
1000ASD |
|
Voltage |
rises to 15V timing |
|
Aging time |
more than 1200 minutes |

Our equipment:

Tight coating without cracks, sufficient content:

Insoluble anode pulse plating copper high aspect ratio slice analysis (12:1)

Insoluble titanium anode high aspect ratio pulse electroplating copper process section (20:1)

Our service:

Size and shape customization

Coating customization

Quality test
Shipping:

Customer feedback:

Iridium Coated Titanium Anode For PCB Reverse Pulse Copper Plating applications:
Copper plating on printed circular boards
Horizontal plating.
Industrial acid copper plating
Hot Tags: iridium coated titanium anode for pcb reverse pulse copper plating, China iridium coated titanium anode for pcb reverse pulse copper plating manufacturers, suppliers, factory, Iridium Coated Titanium Anode for Pcb Reverse Pulse Copper Plating, Ir Coating, Dsa Titanium Anode Ru Ir Coated for Metal Electrowinning, Anode for Electrolysis Metal, Mixed Metal Oxide Titanium Plating Baskets for Copper Plating, Mmo Wire Anode with 1 5 Mm Diameter for Cathodic Protection
You Might Also Like
Send Inquiry






